VOR/ILS Analyzer EVS200
0796.1800.02 E-8 38
Chapter 3: Operation
Command BW0
command function
BW0 <bandwidth information > 8-kHz bandwidth setting
The command BW0 enables the switching over to the 8-kHz bandwidth in the ILS mode and in the
"
level" mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
BW0 <CR>
bw0 <CR>
READY <CR/LF>
READY <CR/LF>
Command BW1
command function
BW1 <bandwidth information> 30-kHz bandwidth setting
The command BW1 enables the switching over to the 30-kHz-IF bandwidth in the ILS mode and in
the "
level" mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
BW1 <CR>
bw1 <CR>
READY <CR/LF>
READY <CR/LF>